30″ x 2.5″ String-Wound Filter Cartridge, Shelco Polypropylene 50 Micron, MS30FP50-B-T (Case Only)

$210.00

  • Removes Dirt, Rust & Sediment
  • 50 Micron Filtration
  • Polypropylene Fibers Meet FDA Guidelines
  • Cartridges are Individually Sleeved and Tagged

This is a 50-micron polypropylene, 30″ x 2.5″ string-wound filter cartridge by Shelco (case only).
  Sold in Case of (15) Cartridges

The MS30FP50-B-T Shelco 50-micron polypropylene 30″ x 2.5″ string-wound filter cartridge case is a bulk replacement option for dependable depth filtration and routine maintenance. String-wound cartridges trap sediment throughout layers of wound media, making them a strong choice for consistent dirt-holding capacity and predictable changeouts. This 50-micron option is typically selected as a coarse first-stage filter to capture larger particles and protect downstream filters, valves, membranes, and equipment.

Model number: MS30FP50-B-T

Micron rating: 50 microns

Media type: String-wound depth filtration cartridge, polypropylene

Sold as: Case only (bulk quantity)
If your product page lists a specific case quantity, keep that number in this field exactly as shown on the page.

Shelco MS Series Flow Rate vs Pressure Drop for the Polypropylene 30" x 2.5" String-Wound Filter Cartridge, Shelco 50 Micron (Case Only)

Cartridge size and housing compatibility

  • Designed for standard-length housings that accept this cartridge size and diameter
  • Confirm your current cartridge length, diameter, and housing style before ordering
  • Match the model number on your current cartridge whenever possible for the fastest compatibility confirmation

What is the MS30FP50-B-T 30″ x 2.5″ String-Wound Filter Cartridge Used For?

  • Coarse sediment prefiltration to capture larger particles before finer filtration stages
  • Pretreatment to protect carbon filters, RO membranes, DI resin, UV systems, and specialty media
  • Whole house and light commercial sediment reduction where particulate causes plugging, wear, or cloudy water
  • Facility maintenance programs where stocking a case reduces downtime and avoids missed service intervals

Compatibility checks
Before ordering, confirm:

  • Your housing accepts the same cartridge length and diameter as your current cartridge
  • Your application can use 50 micron coarse filtration (first-stage capture of larger particulate)
  • If you need finer polishing filtration, use a staged approach (coarse first stage, finer second stage)

Why choose 50 micron

  • Captures larger sediment and debris while maintaining strong flow
  • Often used as the first stage when sediment load is high
  • Helps extend the life of downstream finer filters by reducing the particle load they see

What’s included

  • One case of Shelco MS30FP50-B-T string wound sediment cartridges (case only)

Install difficulty
Easy. Standard cartridge replacement in an existing housing.

Installation Guidance for the MS30FP50-B-T 30″ x 2.5″ String-Wound Filter Cartridge

  1. Shut off water to the filter housing and relieve pressure.
  2. Place a towel or pan under the housing to catch water.
  3. Remove the sump and remove the used cartridge.
  4. Clean the housing sump and inspect the O-ring; replace if flattened, cracked, or nicked.
  5. Insert the new cartridge, reseat the sump, and hand-tighten.
  6. Turn the water on slowly, check for leaks, and flush until the water runs clear.
  7. Recheck for leaks after a few minutes and again later the same day.

Replacement triggers
Replace sediment cartridges when:

  • Flow drops noticeably at fixtures or equipment
  • Differential pressure rises across the housing (if monitored)
  • The cartridge shows heavy discoloration or visible loading
  • You reach your planned maintenance interval for your water conditions and usage

Maintenance Schedule for the MS30FP50-B-T

  • Inspect and replace based on pressure drop, visible loading, or scheduled maintenance
  • Keep spare cartridges on hand for sediment-heavy sources or high-use systems
  • If you use staged filtration, replace the coarse stage when it loads to protect the finer stage

Q: What does a 50-micron string-wound cartridge remove?
A:
It targets larger sediment and particulate matter, such as dirt, sand, silt, and rust flakes, that can clog equipment and cloud water.

Q: Is a 50-micron filter considered coarse?
A:
Yes. It is commonly used as a first-stage sediment filter to protect downstream filtration and maintain a stronger flow.

Q: Will the MS30FP50-B-T string-wound filter cartridge remove chlorine taste and odor?
A:
No. This is a sediment cartridge. Carbon filtration is typically used for chlorine taste and odor.

Q: Can I use this before RO, DI, or UV systems?
A:
Yes. Coarse sediment filtration is commonly used as pretreatment to reduce particulate loading before finer stages.

Q: Is the MS30FP50-B-T string-wound filter cartridge washable?
A:
String-wound cartridges are typically replaced, not washed, because debris is trapped throughout the depth of the media.

Q: How do I confirm the MS30FP50-B-T fits my system?
A:
Match the model number and confirm your current cartridge length and diameter match the housing you have.

Q: Why buy a case instead of a single cartridge?
A:
A case supports planned maintenance, reduces reorder interruptions, and helps avoid downtime in high-use systems.

Stock up with a case of Shelco MS30FP50-B-T 50 micron string-wound cartridges to keep sediment under control, protect downstream filtration, and stay ahead of maintenance.

Example Ordering Guide with Options
MS 10 C S
Product Code Length Media Core
MS 10=10″
20=20″
30=30″
40=40″
B=Fribilated Polypropylene
C=*FDA Bleached Cotton
E=Polyester
F=*FDA Polypropylene
G=Glass Fiber
N=Nylon
P=Industrial Polypropylene
R=Rayon
U=Natural Cotton
W=Industrial Bleached Cotton
P=Polypropylene
S=304 Stainless Steel
G=316 Stainless Steel
T=Tin Steel
10

–
N 2

–
EXP
Micron Core Cover Diameter End Treatment
0.5
1
3
5
10
20
25
30
50
75
100
150
Blank=None
N=Non-Woven
W=Woven
Blank=2-1/2″
2=2″
3=2-3/8″
4=2-3/4″
45=4-1/2″
EXP=PP Core Extender
EXS=SS Core Extender
S3=222 w/ Fin End
S4=222 w/ Flat End
S5=226 w/ Fin End
S6=226 w/ Flat End
S8=SOE w/ Spring
S12=222 w/ Spring
EPR=EPR Gaskets
B=Buna Gaskets
F=Fin End Only
FL=Flat End Only

*FDA cotton and poly meet the FDA guidelines as acceptable for potable and edible liquid contact according to CFR title 21.

Cap Options
Cap Options

Used in 30 inch Shelco Housings

Used in 30″ Shelco Housings

 

Additional information

Cartridge Size

Micron Size

Material Composition

Cartridge Housing Size

Country of Origin